9.7 AT+CGQREQ Quality of service profile (requested)
Description
This command allows the TE to specify a Quality of Service Profile that is used when the MT sends
an Activate PDP Context Request message to the network..
A special form of the set command
(AT+CGQREQ=<cid>) causes the requested profile for context number <cid>
to become
undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command Responses
AT+CGQREQ=? +CGQREQ: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s) [<CR><LF>
+CGQREQ: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s)
[…]]
OK
ERROR
Read Command Responses
AT+CGQREQ?
+CGQREQ: [<cid>, <precedence >, <delay>, <reliability>,
<peak>, <mean>[<CR><LF>
+CGQREQ: <cid>, <precedence >, <delay>, <reliability.>, <peak>
,
<mean>[…]]]
OK
ERROR
Write Command Responses
AT+CGQREQ=<cid>[,<prec
edence>[,<delay>[,<reliabilit
y>[,<peak>[,<mean>]]]]]
OK
ERROR
Execution Command Responses
AT+CGQREQ OK
ERROR
Defined values
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7600 Series and is the answer not in the manual?

SimCom SIM7600 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7600 Series
CategoryControl Unit
LanguageEnglish

Related product manuals