Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
Defined values
0 – disable automatic report
1 – enable automatic report
0 – CSQ automatic report every five seconds
1 – CSQ automatic report only after <rssi> or <ber> is changed
NOTE: If the parameter of <mode> is omitted when executing write command, <mode> will be set
to default value.
Examples
+AUTOCSQ: (0-1),(0-1)
AT+AUTOCSQ?
+AUTOCSQ: 1,1
OK
AT+AUTOCSQ=1,1
+CSQ: 23,0 (when <rssi> or <ber> changing)
4.10 AT+CSQDELTA Set RSSI delta change threshold
Description
This command is used to set RSSI delta threshold for signal strength reporting.
SIM PIN References
NO Vendor
Syntax
AT+CSQDELTA=? +CSQDELTA: (list of supported <delta>s)
OK
Read Command Responses
AT+ CSQDELTA?
+CSQDELTA: <delta>
OK
ERROR