Page #66 background image
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
65
<port>
0 – all ports
1 – use UART port to output URCs
2 – use MODEM port to output URCs
3 – use ATCOM port to output URCs
4 – use cmux vritual port1 to output URCs
5 – use cmux virtual port2 to output URCs
6 – use cmux vritual port3 to output URCs
7 – use cmux vritual port4 to output URCs
Examples
AT+CATR=1
OK
AT+CATR?
+CATR: 1
OK
4.12 AT+CPOF Power down the module
Description
This command is used to power off the module. Once the AT+CPOF command is executed, The
module will store user data and deactivate from network, and then shutdown.
SIM PIN References
NO Vendor
Syntax
Test Command
Responses
AT+CPOF=? OK
Execution Command Responses
AT+CPOF OK
Examples
AT+CPOF
OK