Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
ATD10011;
+CLCC: 1,0,0,0,0,"10011",129,"sm"
OK
RING (with incoming call)
AT+CLCC
+CLCC: 1,1,4,0,0,"02152063113",128,"gongsi"
OK
6.8 AT+CEER Extended error report
Description
Execution command causes the TA to return the information text <report>, which should offer the
user of the TA an extended report of the reason for:
1 The failure in the last unsuccessful call setup(originating or answering) or in-call
modification.
2 The last call release.
3 The last unsuccessful GPRS attach or unsuccessful PDP context activation.
4 The last GPRS detach or PDP context deactivation.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command Responses
AT+CEER=? OK
Execution Command Responses
AT+CEER +CEER:<report>
OK
Defined values
<report>
Wrong information which is possibly occurred.
Examples
+CEER: Invalid/incomplete number