Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
AT+CLVL? +CLVL: <level>
Write Command Responses
ERROR
Defined values
Integer type value which represents loudspeaker volume level. The range is from 0 to 5, and 0
represents the lowest loudspeaker volume level, 4 is default factory value.
NOTE: <level> is nonvolatile, and it is stored when restart.
Examples
AT+CLVL?
OK
AT+CLVL=3
6.24 AT+SIDET Set sidetone
Description
command is used to enable or disable sidetone.
Please refer to related hardware design
document for more information. This command is only used after call start.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
+SIDET: (list of supported <en>s)
OK
Read Command Responses
AT+SIDET? +SIDET: <en>
OK
AT+SIDET=<en> OK
ERROR