EasyManuals Logo

SimCom SIM7600 Series User Manual

SimCom SIM7600 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
135
AT+CLVL? +CLVL: <level>
OK
Write Command Responses
AT+CLVL=<level>
OK
ERROR
Defined values
<level>
Integer type value which represents loudspeaker volume level. The range is from 0 to 5, and 0
represents the lowest loudspeaker volume level, 4 is default factory value.
NOTE: <level> is nonvolatile, and it is stored when restart.
Examples
AT+CLVL?
+CLVL:4
OK
AT+CLVL=3
OK
6.24 AT+SIDET Set sidetone
Description
This
command is used to enable or disable sidetone.
Please refer to related hardware design
document for more information. This command is only used after call start.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+SIDET=?
+SIDET: (list of supported <en>s)
OK
Read Command Responses
AT+SIDET? +SIDET: <en>
OK
Write Command
Responses
AT+SIDET=<en> OK
ERROR
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7600 Series and is the answer not in the manual?

SimCom SIM7600 Series Specifications

General IconGeneral