Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
4 AT Commands for Status Control
4.1 AT+CFUN Set phone functionality
Description
This command is used to select the level of functionality <fun>
in the ME. Level "full
functionality" is where the highest level of power is drawn. "Minimum functionality" is where
min
imum power is drawn. Level of functionality between these may also be specified by
manufacturers. When supported by manufacturers, ME resetting with <rst>
utilized.
NOTE: AT +C FU N =6 must be used after setting AT+CFUN =7. If module in offline
execute AT + C F U N =6 or restart module to online mode.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command Responses
AT+CFUN=? +CFUN: (list of supported <fun>s), (list of supported <rst>s)
OK
ERROR
+CME ERROR: <err>
Read Command Responses
AT+CFUN? +CFUN: <fun>
OK
ERROR
+CME ERROR: <err>
AT+CFUN=<fun>[,<rst>] OK
ERROR
Defined values
<fun>
0 – minimum functionality
1 – full functionality, online mode