Page #249 background image
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
248
10 to 6000.
<SMS time>
a numeric parameter which is number of milliseconds to assert RI delay to reset RI. The range is
10 to 6000.
Examples
AT+CFGRI=?
+CFGRI: (0-1),(10-6000),(20-6000)
OK
AT+CFGRI?
+CFGRI: 0,60,120
OK
AT+CFGRI=1
OK
AT+CFGRI
OK
12.3 AT+CSCLK Control UART Sleep
Description
This command is used to enable UART Sleep or always work,
if set to 1, UART can sleep when DTR pull high
if set to 0, UART always work
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+CSCLK=? +CSCLK: (range of supported <status>s)
OK
Read Command Responses
AT+ CSCLK? +CSCLK: <status>
OK
Write Command
Responses
AT+CSCLK=<status>
OK
ERROR
Execution Command Responses
AT+CSCLK
Set <status> = 0