Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
+CME ERROR: <err>
Defined values
<state>
Indicates the state of PDP context activation:
0 – deactivated
1 – activated
A numeric parameter which specifies a particular PDP context definition (see AT +CGDCONT
command).
1…24,100…179
Examples
AT+CGACT?
+CGACT: 1,1
OK
AT+CGACT=?
OK
AT+CGACT=0,1
9.4 AT+CGDCONT Define PDP context
Description
The set command specifies PDP context para
meter values for a PDP context identified by the
(local) context identification parameter <cid>
. The number of PDP contexts that may be in a
defined state at the same time is given by the range returned by the test command. A special form of
the write command (AT+CGDCONT=<cid>) causes the values for context <cid>
undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command Responses
AT+CGDCONT=? +CGDCONT: (range of supported<cid>s),<PDP_type>
supported <d_comp>s),(list of supported <h_comp>
<ipv4_ctrl>s),(list of <emergency_flag>s)