SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
62
191 -25 dBm or greater
199 not known or not detectable
100…199 – expand to TDSCDMA, indicate RSCP received
<ber>
(in percent)
0 <0.01%
1 0.01% --- 0.1%
2 0.1% --- 0.5%
3 0.5% --- 1.0%
4 1.0% --- 2.0%
5 2.0% --- 4.0%
6 4.0% --- 8.0%
7 >=8.0%
99 not known or not detectable
Examples
AT+CSQ
+CSQ: 22,0
OK
4.9 AT+AUTOCSQ Set CSQ report
Description
This command is used to enable or disable automatic report CSQ info
rmation, when automatic
report enabled, the module reports CSQ information every five seconds or only after <rssi> or
<ber> is changed, the format of automatic report is “+CSQ: <rssi>,<ber>”.
SIM PIN References
NO Vendor
Syntax
Test Command
Responses
AT+AUTOCSQ=? +AUTOCSQ: (list of supported<auto>s),(list of supported<mod
e>s)
OK
Read Command
Responses
AT+AUTOCSQ? +AUTOCSQ: <auto>,<mode>
OK
Write Command Responses
AT+AUTOCSQ=<auto>[,<
OK
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7600 Series and is the answer not in the manual?

SimCom SIM7600 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7600 Series
CategoryControl Unit
LanguageEnglish

Related product manuals