29
YES
V.25ter
Syntax
Read Command Responses
ATS0? <n>
OK
ERROR
Write Command
Responses
ATS0=<n> OK
ERROR
Defined values
<n>
000
Automatic answering mode is disable. (default value when power-on)
001–255 Enable automatic answering on the ring number specified.
NOTE: 1.The S-parameter command is effective on voice call and data call.
2.If <n> is set too high, the remote party may hang up before the call can be answered
automatically.
Examples
ATS0?
000
OK
ATS0=003
OK
3.9 +++ Switch from data mode to command mode
Description
This command is only available during a connecting PS data call. The +++ character sequence
causes the TA to cancel the data flow over the AT interface and switch to Command Mode. This
allows to enter AT commands while maintaining the data connection to the remote device.
NOTE: To prevent the +++
escape sequence from being misinterpreted as data, it must be preceded
and followed by a pause of at least 1000 milliseconds, and the interval between two ‘+’ character
can’t exceed 900 milliseconds.
SIM PIN References
YES
V.25ter
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7600 Series and is the answer not in the manual?

SimCom SIM7600 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7600 Series
CategoryControl Unit
LanguageEnglish

Related product manuals