Argus Radar - INSTALLATION AND SETTINGS
988-10187-004 1.5
WARNING
THE RADAR UNIT IS PROVIDED WITH A SAFETY SWITCH, WHICH
DISABLES ANTENNA ROTATION DURING MAINTENANCE
OPERATIONS AND AVOIDS HIGH VOLTAGE DAMAGE. ALWAYS TURN
THE SAFETY SWITCH OFF, WHENEVER ADVISED IN THIS MANUAL
(FOR INSTANCE, BEFORE PERFORMING ANY MAINTENANCE OR
INSTALLATION PROCEDURE). IGNORING SAFETY SWITCH
OPERATION MAY PRODUCE HAZARD OF ELECTROCUTION AS WELL
AS OTHER SEVERE INJURES
1.3 System Specifications
1.3.1 Dimension and Weight
See outline drawings
1.3.2 Power
Power supply
Single phase 220 or 115 Vac
+/- 15% 50/60 Hz
Power consumption (estimated)
Monitor M5027
68 W (+ 5 W power supply)
Monitor M5024
35 W (+ 5 W power supply)
Monitor M5019
30 W (+ 5 W power supply)
Monitor M5016
25 W (+ 5 W power supply)
Monitor 26” Hatteland 16:10
120 W
Monitor 24” Hatteland
110 W
Core + Keyboard
40 W
1.3.3 Environmental Data
Operating temperature
-15°C / +55°C
Storage temperature
-25°C / +70°C
Relative humidity
Up to 95% at +40°
Water resistance, Salt spray, Vibrations etc. as per IEC 60945