EasyManua.ls Logo

Simrad argus - Vdr Connection; Table 1.10.2 - Monitor Timings

Simrad argus
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Argus Radar - INSTALLATION AND SETTINGS
988-10187-004 1.12
1.11 VDR Connection
To connect a VDR System to the Argus Radar, use the VGA Output on the
Core Unit (Alpha Assy). The maximum distance from the Unit to the VDR
depends on the level of the Video signal output of the cable in use. See the
following table for distances regarding function of cable type.
Cable
Video
1280x1024
Video
1600x1200
Video
1920x1200
(26” wide
screen)
Distance (m)
Distance (m)
Distance (m)
RG75
RG59
M202
M203
RG11
CT100
CT125
10
25
25
35
40
50
60
8
20
20
30
30
40
45
10
25
25
35
40
50
60
Table 1.10.1 VDR Connection
NOTE
- Supported VDR equipment must follow the IMO
recommendation A.861(20)
- The VDR outlet is completely different from the DVI outlet to
which the monitor is connected
Monitor synchronism timings according to the resolution
Resolution 1280x1024 1366x768 1600x1200 1920x1080 1920x1200
Dot Clock
110 MHz 72 MHz 110 MHz 144 MHz 130 MHz
Horizontal
Period
15.56 uS 21.75 uS 16.36 uS 14.7 uS 16 uS
Horizontal Sync
1.67 uS 469 nS 0.908 uS 236 nS 246 nS
Horizontal Front
Porch
392 nS 916 nS 416 nS 458 nS 336 nS
Horizontal Back
Porch
1.86 uS 1.388 uS 496 nS 694 nS 652 nS
Vertical Period
16.41 mS 17.53 mS 19.96 mS 16.48 mS 19.76 mS
Vertical Sync
46.4 uS 87 uS 164 uS 58 uS 96 uS
Vertical Front
Porch
15.6 uS 87 uS 48.8 uS 58.8 uS 48 uS
Vertical Back
Porch
410 uS 652 uS 116 uS 418 uS
Table 1.10.2 Monitor timings

Table of Contents