Argus Radar - RADAR CONFIGURATION
988-10187-004 3.25
3.11.3 MAC Address (Fig 3.11.1 -C)
This is the Ethernet MAC address of the board (not settable). Part of the address is a field
assigned only to Simrad. Less significant bytes are different for any Antares PCB
manufactured.
3.11.4 TXRX Associated by Default (Fig 3.11.1 D)
By pressing the relevant button, the following list with all the transceivers connected will be
displayed:
This is not the interswitch, this list selects the TXRX to use at the start-up of the system.
For example if the Port Argus Console is normally used with TXRX n 2, the selection
“TXRX2” shall be chosen in the left list, and if a blackout occurs or the system is restarted
or completely powered off and on again, the Console will automatically select the TXRX n
2 at the restart.
WARNING
IF THE SETUP HAS TO BE TRANSFERRED FROM CONSOLE TO CONSOLE VIA
A MEMORY STICK, CHECK THAT THE DEFAULT TRANSCEIVER IS NOT THE
SAME FOR ANY OF THE CONSOLES.
3.11.5 General info (Fig 3.11.1 E)
This window shows information regarding the screen resolution, PPI pixel size and the
exact software version installed in the system.