Argus Radar - SERIAL INTERFACE SPECIFICATIONS
988-10187-004 2.11
ZDA Time and date
UTC, day, month, year and local time zone.
$--ZDA, hhmmss.ss, xx, xx, xxxx, xx, xx*hh<CR><LF>
Local zone minutes (see Note),00 to +59
Local zone hours(see Note), 00 h to ±13 h
Year (UTC)
Month, 01 to 12 (UTC)
Day, 01 to 31 (UTC)
UTC
NOTE
Local time zone is the magnitude of hours plus the magnitude of minutes
added, with the sign of local zone hours, to local time to obtain UTC. Local
zone is generally negative for East longitudes with local exceptions near
the International date line.