38
4.12.4 Control, lubricant, and additional specifications
Control circuit boards (12 V / 24 V):
V10 to V13 or V20 to V23: depending
on the type and function of the control
circuit boards used
Renocal FN 745)
Additional specifications:
For hazardous goods
transportation
Version for USA, adapter with
grease fitting with/without SV
(pressure limiting valve), both
NPT thread, (Europ. cable)
Version for USA, adapter with
grease fitting with SV, both NPT
thread (US cable)
With customized accessories
NOTE
The control circuit boards V10 to V13 or V20 to V23 have different functionality. However, the following applies to all
circuit boards:
The lubrication time can be adjusted using a rotary switch, in 8-second- or 2-minute- increments. In the factory
setting, the switch is in position 3 = 24 seconds or 6 minutes.
The pause time can be adjusted using a rotary switch, in 4-minute or 1-hour increments. In the factory setting, the
switch is in position 6 = 24 minutes or 6 hours.