EasyManua.ls Logo

SKF P203 - Faults, Causes, and Remedies

SKF P203
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
11 Faults, causes, and remedies
Table
34
Fault table
Fault
Possible cause
Remedy
P
Pump does not run
•
Power supply to pump interrupted.
– Main machine is switched off
– Pump power cable detached or
defective
– External fuse defective
– The pump is in pause time
– The motor of the pump is faulty
– Internal cable break
• Control circuit board or power supply
board is defective
•
Check whether one of the specified faults
exists, and remedy it according to
responsibility
• Faults outside one's own scope of
responsibility must be reported to the
supervisor for initiation of further measures
• Please contact our Customer Service if you
cannot determine or resolve the error
P
Pump runs, but
supplies either no
lubricant at all or not
enough
• Jam, malfunction within the centralized
lubrication system
• Check valve defective
• Pressure limiting valve defective
• Suction bore in a pump element is
clogged
• Worn pump element
• Air inclusion in the lubricant / under the
follower plate
• Consistency of the lubricant is too high
(at low temperatures)
• Consistency of the lubricant is too low
(at high temperatures)
• Metering device within the centralized
lubrication system is configured
incorrectly
• Check whether one of the specified faults
exists, and remedy it according to
responsibility
• Faults outside one's own scope of
responsibility must be reported to the
supervisor for initiation of further measures
• Please contact our Customer Service if you
cannot determine or resolve the error

Table of Contents