61
11 Faults, causes, and remedies
Table
34
Fault table
Fault
Possible cause
Remedy
P
Pump does not run
Power supply to pump interrupted.
Main machine is switched off
Pump power cable detached or
defective
External fuse defective
The pump is in pause time
The motor of the pump is faulty
Internal cable break
Control circuit board or power supply
board is defective
Check whether one of the specified faults
exists, and remedy it according to
responsibility
Faults outside one's own scope of
responsibility must be reported to the
supervisor for initiation of further measures
Please contact our Customer Service if you
cannot determine or resolve the error
P
Pump runs, but
supplies either no
lubricant at all or not
enough
Jam, malfunction within the centralized
lubrication system
Check valve defective
Pressure limiting valve defective
Suction bore in a pump element is
clogged
Worn pump element
Air inclusion in the lubricant / under the
follower plate
Consistency of the lubricant is too high
(at low temperatures)
Consistency of the lubricant is too low
(at high temperatures)
Metering device within the centralized
lubrication system is configured
incorrectly
Check whether one of the specified faults
exists, and remedy it according to
responsibility
Faults outside one's own scope of
responsibility must be reported to the
supervisor for initiation of further measures
Please contact our Customer Service if you
cannot determine or resolve the error