8.5 Reading Off the Software Package Version
Requirement:
☐ You must be a Standard user, Installer or PV system administrator (see Section13.1,
page120).
Procedure:
1. Select Configuration > Device overview in the page and menu selection.
2. In the device line and the Parameters column, select .
☑ You can read off the software package version in the parameter list.
8.6 Configuring the Energy Meter
Requirement:
☐ You must have the user role Installer or PV System Administrator (see Section13.1,
page120).
Procedure:
1. Call up the device properties of the SunnyHomeManager (see Section8.2, page66).
2. Select [Edit].
☑ The menu for setting the device properties opens.
3. In the drop-down lists located in the area Meter Configuration, select the energy meter type
that is connected to the respective meter input:
Connected energy meter type Drop-down list
Energy meter with D0interface
• Select D0.
Bidirectional meter with D0 interface
• Select D0.
• Activate the field Bidirectional meter
(Supply and feed-in).
☑ The area Meter input 2 is not
available.
Energy meter with S0interface
• Select S0.
• In the text field S0 pulses/kWh,
specify the pulse rate of the energy
meter (see energy meter manual).