-60-
No.EX※※-OMX1011
•SI unit parameters (2)
No.
Parameter
Definition
Item
Content
Default
setting
Parameter
setting range
8
Valve
ON/OFF
counter
Generates error
when the operation
count exceeds the
set value.
3
Enable
Generates an error.
Val: 1 to 65000
4
Channel
Disable
Does not generate an
error.
9
Valve
ON/OFF
counter clear
Clears the valve
ON/OFF counter to
0. (Refer to page
131 for the clear
method).
-
-
-
-
10
BUS IN port
setting
Sets the
communication
speed and
communication
method of BUS IN.
Auto
Selects the required
communication speed
and communication
method
Unit
10 HDX
10 FDX
100 HDX
100 FDX
11
BUS OUT
port setting
Sets the
communication
speed and
communication
method of BUS
OUT.
Auto
Selects the required
communication speed
and communication
method.
Unit
10 HDX
10 FDX
100 HDX
100 FDX
1: This function is valid only when "Hold/Clear priority" of the system parameter is set to "Via software".
2: Some PLC does not support an idle mode.
3: The count is memorized every hour. When the power supply is turned on again, counting starts from the last value memorized.
4: Times for setting is set value x1000 times.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks EX600-SEN3 and is the answer not in the manual?

SMC Networks EX600-SEN3 Specifications

General IconGeneral
BrandSMC Networks
ModelEX600-SEN3
CategoryI/O Systems
LanguageEnglish

Related product manuals