EasyManua.ls Logo

SMC Networks EX600-SEN3 - Page 76

Default Icon
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-75-
No.EX※※-OMS0027
Channel parameter object (1) (Class: 79h to 7Fh)
Class Instance Attribute Access Name Type Value
79h
Open circuit detection
•SI
•Digital input (DX
C1)
•Digital output, I/O
BOOL
0: Disable
1: Enable
7Ah
ON/OFF count upper limit
detection
•SI
•Digital input, output, I/O
BOOL
0: Disable
1: Enable
7Bh
ON/OFF count upper limit value
•SI
•Digital input, output, I/O
UINT
1 to 65000
(Times diagnosis is detected=Set
value x1000)
7Ch
Analogue user setting value upper
limit detection
•Analogue input, output, I/O
BOOL
0: Disable
1: Enable
7Dh
Analogue user setting value of
upper limit
•Analogue input, output, I/O
UINT
2 bytes AD value
Refer to "Parameter Setting" for
details.
7Eh
Analogue user setting value lower
limit detection
•Analogue input, output, I/O
BOOL
0: Disable
1: Enable
7Fh
01h to
0Ah
1
64h to
83h
2
Get/Set
Analogue user setting value of
lower limit
•Analogue input, output, I/O
UINT
2 bytes AD value
Refer to "Parameter Setting" for
details.
1: The instance number 01h to 0Ah is allocated to the Unit No. from 0 to 9.
2: The attribute number from 64h to 83h is allocated to the channel No. from 0 to 31.

Table of Contents

Related product manuals