Thefollowingtable,Figure21andFigure22detailcabletypesandconnectionsofonebattery(LG-chem
Resu10H).Preparecablesandconnectasdescribedinthefollowingtable:
StorEdge
Connection Unit
connection
LG Chem
RESU10H
battery
connection
Connection method
to the
Connection Unit
Recommended cable
type
(min-max AWG)
DC
BAT + terminal block DC+
o
Insert a flat blade
screwdriver into the
square opening at the top
of the terminal block and
press to open clamp
mechanism.
o
Insert the wire into the
round opening and
release the screwdriver
to spring back and clamp
the wire.
DC cable 10 AWG (10-14
AWG), 600V insulated.
BAT - terminal block DC-
Control and monitoring
5-pin communication
terminal block:
6-pin connector
Press the protrusion at the
top of the terminal block to
open the connection hole,
insert the wire and release to
spring back and clamp the
wire.
5-wire shielded twisted pair
cable 24 AWG (16-24AWG),
600V insulated.
CAT5 600V insulated can
also be used.
En (Enable) ENABLE_H
V+ Not connected
B- (RS485)
1
RS485_L -
2
A+ (RS485)
1
RS485_H +
2
G (RS485) EN_G
1
Must be twisted pair
2
Must be twisted pair
Chapter 6: StorEdge Inverter Connections
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
35