Step 2: Pairing Power Optimizers to the Inverter
Onceallconnectionsaremade,allthepoweroptimizersmustbelogicallypairedtotheirinverter.The
poweroptimizersdonotstartproducingpoweruntiltheyarepaired.Thisstepdescribeshowtoassign
eachinvertertothepoweroptimizersfromwhichitwillproducepower.
Performthisstepwhenthemodulesareexposedtosunlight.Ifthestringlengthischangedorapower
optimizerisreplaced,repeatthepairingprocess.
1.
Performpairing:PressandholddowntheinverterLCDbuttonforabout10 seconds.Thefollowing
messageisdisplayed:
K e e p h o l d i n g b u t t o n
f o r p a i r i n g , r e l e a s e
t o e n t e r m e n u . . .
R e m a i n i n g : 3 s e c
Keepholdingfor5secondsuntilthefollowingisdisplayed:
P a i r i n g
T u r n S w i t c h T o O n
2.
TurntheinverterON/OFFswitchtoONwithin5seconds.Ifyouwaitlongerthan5secondsthe
inverterexitsthepairingmode.Thefollowingmessageisdisplayedindicatingthattheinverteris
performingthepairing:
P a i r i n g
R e m a i n i n g [ s e c ] : 1 8 0
3.
Waitforthecompletionofthepairing(remainingsecondsis0).Ifpairingfails,anerrorisdisplayed.In
thiscase,repeatthepairingsteps,andrefertoPowerOptimizerTroubleshootingonpage96.Ifthe
problempersists,contactSolarEdgeSupport.Whenpairingsucceeds,thefollowingmessageis
displayed:
P a i r i n g
P a i r i n g C o m p l e t e d
Thesystemstartupprocessbegins:
SincetheinverterisON,thepoweroptimizersstartproducingpowerandtheinverterstartsconverting
AC.
WARNING!
When you turn ON the inverter ON/OFF switch, the DC cables carry a high voltage and the power
optimizers no longer output a safe 1V output.
Après avoir mis l'interrupteur ON/OFF de l'onduleur monophasé sur ON, les câbles DC portent une
haute tension et les optimiseurs de puissance ne rent plus la tension de sécurité de 1V.
WhentheinverterstartsconvertingpoweraftertheinitialconnectiontotheAC,theinverterenters
Wakeupmodeuntilitsworkingvoltageisreached.Thismodeisindicatedbytheflickeringgreeninverter
LED.
WhiletheinverterisinWakeupmode,itmonitorsthegridandverifiescorrectgridvoltageandfrequency.
Thefollowingmessageisdisplayed:
Chapter 7: Commissioning the Installation
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
49