LI/ limits check
item
LL local SD /
sweep
up/down
LV0,F
limits check:
lower
limit
SFF
log
sweep: points/sweep
LV1,F limits
check: upper
limit
SI
single
measurement
SMO go
to
next mini-status
page
MA?
statistics
query:
maximum
SMI
go to
previous mini-status
page
MCI file clear: auto/manual
sou
display:
source
MD / analyzer mode
SP F step
vernier
ME I analyser monitor
SR / store
result
MI?
statistics query:
minimum SSI store
set-up
MS F analyzer
delay
STO program status
MU?
statistics query: mean
STl
microprocessor
status
ST2 interface status
NA? file
query: readings
accepted ST3 store status
NL / null ST4 file status
NO/ normalize ST
5
scaling function status
NR? file
query:
readings taken ST6 scaling constant status
ST7 results status
01/ plotter Y-axis
overlay
item ST8 statistics status
OLI plotter Y-axis o'lay
limits:
auto/man.
S
V/ serial poll configure (GPIB)
OMO,F plotter Y-axis overlay limits: min.
SW /
sweep enable
OM1.F plotter Y-axis
overlay
limits: max.
S
XI
staticised result
OP1 ,/
data output (RS423)
OP2J data output (GPIB) TI text
plotter title
OP3,/
data output (File) TM
/,/
set
time
OS/
command separator (GPIB) TS? test
results query
OT / command
terminator
(GPIB) TTO
self test
OUl,/ input VI:
grounded/floating TT1
initialize
OU2,/ input
V2: grounded/floating
TT2
reset
oz /
plotter Y-axis overlay log/lin
UW/
display: phase normal/unwrapped
PA/
plotter axes
PC?
place
of last
calibration
VA F
generator voltage amplitude
PC texi calibration
place VB F generator
voltage
bias
PD/
plotter
device VC F monitor voltage
limit
PGO
go to next status
page
VE / plotter mode
PG1
go to previous
status page
VF
F
parameter 1 value
PL
plot (from File)
VL F
parameter 2 value
PN I?
program query
(length) VI/ display:
variable
PP /
parallel poll configure (GPIB)
VMF sweep
limits: V amplitude min.
PS/
parallel poll
sense (GPIB) VN? version
number
PT/
plotter text
enable VP/ plotter
Y-axis overlay
pen
VRO frequ^icy vernier
QMF
sweep limits: I bias,
min. VR1 amplitude
vernier
QXF sweep
limits: I bias, max.
VR2 bias
vernier
VR3 plotter
X-min. vernier
RA1JT input VI
range VR4 plotter Y-min. vernier
RA2,/
input V2 range
VR5 plotter X-max.
vernier
RA3,I
input I range
VR6 plotter Y-max.
vernier
RE
recycle
measurements VS? statistics query: variance
RH /
data
output:
heading
VXF sweep limits: V amplitude max.
RM
remote
RP/
command
separator (RS423) WF
/
calibration waveform
RR
/
output mode
(RS423) WK / calibration week
RS/
recall set-up
WK? week of last calibration
RT/
command terminator
(RS423)
JWS/1260/2
8.15