COMMAND
INDEX
CF /
clear
function
Note: In the
remote
commands
listed
below
01/
display:
current
coordinates
/=
integer, CL clear error
message
F=
floating point number. CM/ calibration
mode
CO I,I,F,F
scaling constant
#B
edit
program:
go to
previous
line
CP
pause/continue (program)
#C/ clear
program CVI
display: voltage coordinates
#D
edit program:
delete cs /
clear
set-up
#E
/
edit program CY / display: admittance coordinates
#F edit program:go
to next line
CZI display: impedance coordinates
#1 edit program:
insert
#K
/,/ copy program DC1
,/
input VI coupling
#L
/
learn program DC2,/ input
V2
coupling
#P/ list program DC3,/ input I coupling
#Q
quit program DE / scaling: dev A
OFF Forcing waveform frequency
*CLS clear status
DO output last
result
*ESE
event
status
enable DS
/
scaling: dev A store
*ESE?
event status enable query DV? standard deviation
query
*ESR?
event status register query
*IDN?
identification query EC /
output
echo
(RS423)
*OPC operation complete EP
/
execute program
*RCL
recall ER? last error query
*RST
reset
*SAV
save FC clear File
*SRE
service request enable
FBI
display file
*SRE?
service request enable
query FG /
file format
*STB?
read
status byte query FL / output file line
*TST? self-test
query FMF sweep limits: frequency min.
FO output file
AA
/
plotter scaling: size FP /? file
query:
blocks filed/pointer
AE F
monitor errors FRF generator frequency
AI?
auto-integration time query
FU I, text
scaling function
ARl?
range query, voltage 1 input F
VI display: function coordinates
AR2? range query, voltage 2 input FXF sweep
limits: frequency max.
AR3? range query, current input
AVI analyzer auto-integration
GDI plotter grid
GNF group delay, negative
BC I binsort A:
step size GPF group delay, positive
BFF no. of meas.
(n) after stop GT / generator
type
BG I binsort B:
logic sense
BK break
HFF linear sweep:
units/step
BLF binsort
A: bin min.%
HS sweep hold
BM F sweep
limits: V bias min.
BN/ binsort
A: enable IAF
generator current amplitude
BP/ error
beep IBF generator current bias
BR / binsort
B: no. of retries
ICF monitor current limit
ESI
binsort
A: stop after n meas.
IMF sweep limits: I amplitude
min.
BVF
binsort A: bin max.%
IX F sweep limits: I amplitude
max.
BV/
binsort
B: logic levels
IP1 ,/ input V 1 single/diff.
BXF
sweep limits: V bias max.
IP2,/ input V2 single/diff.
BZ /
binsort A: bin number
ISF analyzer integration
time
CAF
ideal calibration value
JP / jump to program line no.
cc
/
display: circuit
CE clear error
codes
LFF linear sweep: points/sweep