Page 7-18 AWS δelta Operator’s Manual
Automation
OPERATION
Activating the Automation System
Use the softkeys below the centre section TFT to select SSL then Auto. This calls up the main automation display with
its associated soft key menu (see next page).
List Mix Menu
The List Mix menu is the main file menu for the automation system, and shows a list of stored Mix Passes.
New Mix Passes are auto-numbered starting at ‘1’. If a Mix Pass is deleted (see below) then its number will not be re-used.
The only exception to this is if all Mix Passes are deleted. The numbering will then restart from ‘1’. Mix Passes can be
renamed from the AWS Remote — see Renaming Mix Passes.
Changing the selected Mix Pass
The left-hand encoder can be used to scroll through the list of Mix Passes. A yellow cursor band indicates which Mix Pass
is currently selected for modification. The encoder’s push-push switch can be used to either start a New Mix, or select a
previous Mix Pass. Note that once a Mix is selected, the Mix may take a moment to load.
Deleting Mix Passes
Mix Passes can be deleted by selecting the Mix Pass you wish to delete, holding down the Delete soft key and pressing
the Confirm soft key.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solid State Logic AWS DELTA 916 and is the answer not in the manual?

Solid State Logic AWS DELTA 916 Specifications

General IconGeneral
BrandSolid State Logic
ModelAWS DELTA 916
CategoryRecording Equipment
LanguageEnglish

Related product manuals