AWS δelta Operator’s Manual Page 7-31
Automation
MIDI SYSEX LOAD
F
or legacy purposes, it is possible to load Automation setups which have been saved via a MIDI SysEx dump. The AWS
uses MIDI port 4 for loading mixes.
Note that MIDI port 4 is also used for MTC. SysEx data will interfere with MTC transmission, so ensure these tracks are
muted while mixing.
• Locate the DAW to just before
the SysEx data containing the
M
ix Passes you wish to load.
• Press the MIDI Load soft key.
• Press the Load soft key.
• Play through the SysEx block of
data. As soon as the AWS
detects the start of valid data it
will delete all the current Mix
Passes and replace them with
the stored ones from the MIDI
track.
Because the Load process replaces
your current Mix Passes with the
ones stored on your Mac or PC
you should check you have saved
any Mix Passes you wish to keep
before loading new ones.
M
IDI Load key