NOTES RELATING TO CONSOLE LOCATION AND AIR CONDITIONING
Any item of electronic equipment can be affected by electrostatic discharge. It is considered good practice to avoid
using fully insulating floor coverings in technical areas.
Air conditioning may sometimes be required; note however, that a cool and dry atmosphere can significantly
increase the likelihood of a build-up of static charge. It is recommended that air conditioning systems are designed
such that the relative humidity does not fall below 30% during periods of operation.
Appendices
AWS δelta Owner’s Manual Appendices Page A-7
DENVIRONMENTAL SPECIFICATION
Temperature Operating: 5 to 30 Deg. C
N
on-operating: -20 to 50 Deg. C
Max. Gradient: 15 Deg. C/Hour
Relative Humidity Operating: 30 to 80 %
Non-operating: 5 to 90 %
Max. Wet bulb: 29 Deg. C (non-condensing)
Vibration Operating: < 0.2 G (3 - 100Hz.)
Non-operating, power off: < 0.4 G (3 - 100Hz.)
Shock Operating: < 2 G (10mSec. Max.)
Non-operating: < 10 G (10mSec. Max.)
Altitude Operating: 0 to 3,000 m
(Above sea level) Non-operating: 0 to 12,000 m