Description of the BMK-8i ACCU stud welding device
Operating Instructions Soyer Bolzenschweißtechnik 33
7.4.1 Maximum settings
The following table indicates the maximum welding time that can be achieved with
the corresponding welding current. Impermissibly high combinations are prevent-
ed by the device electronics and cannot be set. The table is thus provided for in-
formation purposes only.
Information table showing possible maximum setting combinations
Welding current Welding time
100A 500ms
110 A 500 ms
120A 500ms
130A 500ms
140A 500ms
150A 500ms
160A 500ms
170A 500ms
180A 480ms
190A 460ms
200A 440ms
210A 420ms
220A 400ms
230A 380ms
240A 360ms
250A 340ms
260A 320ms
270A 300ms
280A 280ms
290A 260ms
300A 250ms