66 Operating Instructions Soyer Bolzenschweißtechnik
13.1.2 Adjusting welding current and welding time
If no values have been specified, the table in chapter “13.1.1 Support tables for
device settings” on page 65 may help you to adjust the basic settings.
Adjusting welding current and welding time
Step 1: Connect the device as described in chapter “12.2 Connection of
the stud welding device and the stud welding guns” on page 59.
Step 2: Use the arrow keys ↑↓ to
select the position for the
welding current setting.
If selected correctly, the
LED lights up.
Step 3: Use the +/- keys to set the
desired value for the welding
current on the display.
The welding current is adjusted.
Step 4: Use the arrow keys ↑↓ to
select the position for the
welding time setting.
If selected correctly, the
LED lights up.
Step 5: Use the +/- keys to set the
desired value for the welding
time on the display.
The welding time is adjusted.
+