EasyManua.ls Logo

SSD 605C - Page 230

SSD 605C
236 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Application Macros 15-16
605C Frequency Inverter
DIGITAL INPUT 7
VALUE [728]
FALSE
FALSE [727] INVERT
DIGITAL INPUT 6
VALUE [726]
FALSE
FALSE [725] INVERT
DIGITAL INPUT 8
VALUE [730]
FALSE
FALSE [729] INVERT
VALUE FUNC 1
OUTPUT [133]
0.00 %
0.00 %
[130] INPUT A
0.00 %
[131] INPUT B
0.00 %
[132] INPUT C
A+B+C
[134] TYPE
VALUE FUNC 3
OUTPUT [143]
0.00 %
0.00 %
[140] INPUT A
0.00 %
[141] INPUT B
0.00 %
[142] INPUT C
BINARY DECODE
[144] TYPE
VALUE FUNC 5
OUTPUT [153]
0.00 %
0.00 % [150] INPUT A
0.00 %
[151] INPUT B
0.00 %
[152] INPUT C
SWITCH (A,B)
[154] TYPE
VALUE FUNC 9
OUTPUT [173]
0.00 %
0.00 % [170] INPUT A
0.00 %
[171] INPUT B
0.00 %
[172] INPUT C
SWITCH(A,B)
[174] TYPE
VALUE FUNC 2
OUTPUT [138]
0.00 %
0.00 % [135] INPUT A
0.00 %
[136] INPUT B
0.00 %
[137] INPUT C
A+B+C
[139] TYPE
VALUE FUNC 6
OUTPUT [158]
0.00 %
0.00 % [155] INPUT A
0.00 %
[156] INPUT B
0.00 % [157] INPUT C
SWITCH(A,B)
[159] TYPE
ANALOG INPUT 1
VALUE [ 16] 0.00 %
BREAK [ 18] FALSE
100.00
%
[ 14] SCALE
0.00 % [ 15] OFFSET
0..+10 V [ 13] TYPE
FALSE [ 12] BREAK ENABLE
0.00 % [ 17] BREAK VALUE
ANALOG INPUT 2
VALUE [ 25] 0.00 %
BREAK [ 27] FALSE
100.00
%
[ 23] SCALE
0.00 % [ 24] OFFSET
0..+10 V [ 22] TYPE
FALSE [ 21] BREAK ENABLE
0.00 % [ 26] BREAK VALUE
ANALOG INPUT 3
VALUE [715] 0.00 %
BREAK [717] FALSE
100.00 % [713] SCALE
0.00 % [714] OFFSET
0..20 mA [712] TYPE
TRUE [711] BREAK ENABLE
0.00 % [716] BREAK VALUE
PRESET 1
OUTPUT 1 [356]
0.00 %
OUTPUT 2 [372]
0.00 %
INPUT 0 [355] SELECT INPUT
0.00 %
[347] INPUT 0
0.00 %
[348] INPUT 1
0.00 %
[349] INPUT 2
0.00 %
[350] INPUT 3
0.00 %
[351] INPUT 4
0.00 %
[352] INPUT 5
0.00 %
[353] INPUT 6
0.00 %
[354] INPUT 7
RAISE/LOWER
OUTPUT [325]
0.00 %
FALSE
[327] RAISE INPUT
FALSE
[328] LOWER INPUT
10.0 s [326] RAMP RATE
100.00 %
[330] MAX VALUE
0.00 %
[329] MIN VALUE
0.00 %
[331] RESET VALUE
FALSE
[332] RESET
ITEM 2
ITEM 3
(8)
(20)
(9)
(26)
(12)
(13)
(14)
(15)
(16)
(19)
(17)
(32)
(23)
(18)
(22)
(10)
(11)
(30)
INPUT C of VALUE FUNC 5 represents the
584S parameter AUTO SETPOINT select
INPUT C of VALUE FUNC 9 represents the
584S parameter MANUAL SETPOINT select
Macro 99: 584S Compatible Application

Table of Contents