Application Macros 15-13
605C Frequency Inverter
FALSE
0.00%
ANALOG INPUT 2
VALUE [ 25] –
BREAK [ 27] –
100.00% – [ 23] SCALE –
0.00% – [ 24] OFFSET –
0..+10V – [ 22] TYPE –
FALSE – [ 21] BREAK ENABLE –
0.00% – [ 26] BREAK VALUE –
FALSE
0.00%
ANALOG INPUT 1
VALUE [ 16] –
BREAK [ 18] –
100.00% – [ 14] SCALE –
0.00% – [ 15] OFFSET –
0..+10V – [ 13] TYPE –
FALSE – [ 12] BREAK ENABLE –
0.00% – [ 17] BREAK VALUE –
DIGITAL INPUT 1
VALUE [ 31]
–
FALSE
FALSE – [ 30] INVERT
–
DIGITAL INPUT 3
VALUE [ 37]
–
FALSE
FALSE – [ 36] INVERT
–
DIGITAL INPUT 5
VALUE [ 43]
–
FALSE
FALSE – [ 42] INVERT
DIGITAL INPUT 2
VALUE [ 34] – FALSE
FALSE – [ 33] INVERT
–
FALSE
DIGITAL INPUT 4
VALUE [ 40] –
TRUE – [ 39] INVERT
–
FALSE
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
TRUE
SEQUENCING LOGIC
TRIPPED [289]
–
RUNNING [285]
–
JOGGING [302]
–
STOPPING [303]
–
OUTPUT CONTACTOR [286]
–
SWITCH ON ENABLE [288]
–
SWITCHED ON [306]
–
READY [287] –
SYSTEM RESET [305]
–
MAIN SEQ STATE [301]
–
START ENABLED
REMOTE REV OUT [296]
–
HEALTHY [274]
–
FALSE
–
[291] RUN FWD
–
FALSE
–
[292] RUN REV
–
FALSE
–
[293] /STOP
–
–
[280] JOG
–
TRUE
–
[276] DRIVE ENABLE
–
TRUE
–
[277] /FAST STOP
–
TRUE
–
[278] /COAST STOP
–
–
[294] REMOTE REVERSE
–
–
[282] REM TRIP RESET
–
TRUE
–
[290] TRIP RST BY RUN
–
FALSE
–
[283] POWER UP START
–
FALSE
FALSE
FALSE
I/O TRIPS
– [234] EXTERNAL TRIP
–
–
[235] INPUT 1 BREAK
–
–
[236] INPUT 2 BREAK
–
I*t TRIP
105.00% – [237] I*t THRESHOLD
–
60s
–
[238] I*t TIME
–
150.00%
–
[239] I*t UPPER LIMIT
–
STALL TRIP
100.00% – [240] STALL LIMIT –
600.0s
–
[241] STALL TIME
–
TRIPS HISTORY
TRIP 1 [NEWEST] [500]
–
NO TRIP
TRIP 2 [501]
–
NO TRIP
TRIP 3 [502]
–
NO TRIP
TRIP 4 [503]
–
NO TRIP
TRIP 5 [504]
–
NO TRIP
TRIP 6 [505]
–
NO TRIP
TRIP 7 [506]
–
NO TRIP
TRIP 8 [507]
–
NO TRIP
TRIP 9 [508]
–
NO TRIP
TRIP 10 [OLDEST] [509]
–
NO TRIP
MINIMUM SPEED
OUTPUT [335]
–
0.00%
0.00% – [336] INPUT
–
-100.00%
–
[337] MINIMUM
–
PROP. W/MIN.
–
[338] MODE
–
JOG
10.0 0%– [246] SETPOINT
–
1.0s
–
[261] ACCEL RATE
–
1.0s
–
[262] DECEL RATE
–
ANALOG OUTPUT 1
0.00% – [ 45] VALUE –
100.00%
–
[ 46] SCALE
–
0.00%
–
[ 47] OFFSET
–
TRUE
–
[ 48] ABS
–
0..+10V
–
[ 49] TYPE
–
SETPOINT SCALE
OUTPUT [ 59]
–
0.00% lf
0.00% – [ 58] INPUT
–
* 50.0Hz
–
[ 57] MAX SPEED
–
ZERO SPEED
AT ZERO SPEED [360]
–
– [358] INPUT
–
–
[357] LEVEL
–
–
[359] BAND
–
DIGITAL OUTPUT 1
FALSE – [ 52] VALUE –
TRUE
–
[ 51] INVERT
–
DIGITAL OUTPUT 2
FALSE – [ 55] VALUE –
FALSE
–
[ 54] INVERT
–
0.00%
VALUE FUNC 1
OUTPUT [133]
–
0.00%
–
[130] INPUT A
–
0.00%
–
[131] INPUT B
–
0.00%
–
[132] INPUT C
–
A+B+C
–
[134] TYPE
–
REFERENCE
SPEED DEMAND [255]
–
0.00 %
SPEED SETPOINT [254]
–
0.00 %
REVERSE [256]
–
FALSE
LOCAL SETPOINT [247]
–
0.00 %
LOCAL REVERSE [250]
–
FALSE
COMMS SETPOINT [269]
–
0.00 %
0.00%
–
[245] REMOTE SETPOINT
–
0.00%
–
[248] SPEED TRIM
–
100.00%
–
[252] MAX SPEED CLAMP
–
-100.00 %
–
[253] MIN SPEED CLAMP
–
FALSE
–
[243] TRIM IN LOCAL
–
–
[249] REMOTE REVERSE
–
STOP
RAMPED – [279] RUN STOP MODE
–
10.0s
–
[263] STOP RATE
–
0.10%
–
[266] STOP ZERO SPEED
–
0.500s – [284] STOP DELAY –
RAMPED
–
[304] FAST STOP MODE
–
30.0s
–
[275] FAST STOP LIMIT
–
0.1s
–
[264] FAST STOP RATE
–
1200Hz/s
–
[126] FINAL STOP RATE
–
(1)
(9)
(2)
(10)
(14)
(22)
(16)
(18)
(3)
(4)
(5)
(6)
(7)
(17)
SYSTEM RAMP
RAMPING [698]
–
FALSE
LINEAR
–
[244] RAMP TYPE
–
**10.0s
–
[258] ACCEL RATE
–
**10.0s
–
[259] DECEL RATE
–
**10.0s – [267] SYMETRIC RATE –
FALSE
–
[268] SYMETRIC MODE
–
FALSE
–
[260] RAMP HOLD
–
TRUE
–
[691] SRAMP CONTINUOUS
–
10.00%
–
[692] SRAMP ACCEL
–
10.00%
–
[693] SRAMP DECEL
–
10.00%
–
[694] SRAMP JERK 1
–
10.00% – [695] SRAMP JERK 2 –
10.00%
–
[696] SRAMP JERK 3
–
10.00%
–
[697] SRAMP JERK 4
–
0.50%
0.00%
TRUE
TRIPS STATUS
ACTIVE TRIPS [ 4]
–
0000
ACTIVE TRIPS+ [740]
–
0000
WARNINGS [ 5]
–
0000
WARNINGS+ [741]
–
0000
FIRST TRIP [ 6]
–
NO TRIP
0600 – [231] DISABLED TRIPS
–
0000 – [742] DISABLED TRIPS+
–
FALSE – [760] INVERT THERMIST
–
(12)
(13)
VALUE FUNC 2
OUTPUT [138]
–
– [135] INPUT A
–
–
[136] INPUT B
–
–
[137] INPUT C
–
A+B+C
–
[139] TYPE
–
0.00%
(11)
0.00%
ENCODER
POSITION [748] – 0
SPEED Hz [568] – 0.0 Hz
SPEED RPM [569] – 0 n/min
SPEED % [749] –
QUADRATURE – [565] MODE –
FALSE – [747] RESET –
1000
–
[566] LINES
–
FALSE
–
[567] INVERT
–
10.0V
–
[761] SUPPLY
–
PID
PID OUTPUT [320]
–
PID ERROR [766]
–
0.00 %
– [310] SETPOINT
–
–
[764] FEEDBACK
–
FALSE
–
[763] SETPOINT NEGATE
–
FALSE
–
[765] FEEDBACK NEGATE
–
–
[311] ENABLE
–
FALSE
–
[312] INTEGRAL DEFEAT
–
1.0
–
[313] P GAIN
–
1.00 s
–
[314] I TIME CONST
–
0.000 s
–
[315] D TIME CONST
–
2.000 s
–
[316] FILTER TC
–
8.00 %
–
[317] OUTPUT POS LIMIT
–
-8.00
%
–
[318] OUTPUT NEG LIMIT
–
1.0000
–
[319] OUTPUT SCALING
–
(8)
(20)
(15)
(19)
OPERATOR MENU
1 – [93] STARTUP SCREEN
–
255
–
[626] OPERATOR MENU 2
–
591
–
[627] OPERATOR MENU 3
–
67
–
[628] OPERATOR MENU 4
–
72
–
[629] OPERATOR MENU 5
–
75
–
[630] OPERATOR MENU 6
–
370
–
[631] OPERATOR MENU 7
–
319
–
[632] OPERATOR MENU 8
–
313
–
[633] OPERATOR MENU 9
–
314
–
[634] OPERATOR MENU 10
–
315
–
[635] OPERATOR MENU 11
–
316
–
[636] OPERATOR MENU 12
–
310
–
[637] OPERATOR MENU 13
–
764
–
[638] OPERATOR MENU 14
–
766
–
[639] OPERATOR MENU 15
–
(21)
Macro 6: Closed-Loop Speed Feedback

Table of Contents