EasyManua.ls Logo

SSD 605C - Macro 99: 584 S Compatible Application

SSD 605C
236 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Application Macros 15-15
605C Frequency Inverter
DIGITAL INPUT 1
VALUE [ 31]
–
FALSE
FALSE – [ 30] INVERT
–
DIGITAL INPUT 3
VALUE [ 37]
–
FALSE
FALSE – [ 36] INVERT
–
DIGITAL INPUT 5
VALUE [ 43]
–
FALSE
FALSE – [ 42] INVERT
–
DIGITAL INPUT 2
VALUE [ 34]
–
FALSE
TRUE – [ 33] INVERT
–
DIGITAL INPUT 4
VALUE [ 40]
–
FALSE
TRUE – [ 39] INVERT
–
ANALOG INPUT 4
VALUE [722] – 0.00 %
BREAK [724] – FALSE
150.00 % – [720] SCALE –
0.00 % – [721] OFFSET –
0..+10 V – [719] TYPE –
FALSE – [718] BREAK ENABLE –
0.00 % – [723] BREAK VALUE –
SEQUENCING LOGIC
TRIPPED [289] – FALSE
RUNNING [285]
–
FALSE
JOGGING [302]
–
FALSE
STOPPING [303]
–
FALSE
OUTPUT CONTACTOR [286]
–
FALSE
SWITCH ON ENABLE [288]
–
FALSE
SWITCHED ON [306]
–
TRUE
READY [287]
–
FALSE
SYSTEM RESET [305]
–
TRUE
MAIN SEQ STATE [301]
–
NOT READY
REMOTE REV OUT [296]
–
FALSE
HEALTHY [274]
–
FALSE
FALSE
–
[291] RUN FWD
–
FALSE
–
[292] RUN REV
–
FALSE
–
[293] /STOP
–
FALSE
–
[280] JOG
–
TRUE
–
[276] DRIVE ENABLE
–
TRUE
–
[277] /FAST STOP
–
TRUE
–
[278] /COAST STOP
–
FALSE
–
[294] REMOTE REVERSE
–
FALSE
–
[282] REM TRIP RESET
–
TRUE
–
[290] TRIP RST BY RUN
–
FALSE
–
[283] POWER UP START
–
I/O TRIPS
FALSE – [234] EXTERNAL TRIP
–
FALSE
–
[235] INPUT 1 BREAK
–
FALSE
–
[236] INPUT 2 BREAK
–
VALUE FUNC 7
OUTPUT [163]
–
0.00 %
100.00 % – [160] INPUT A
–
0.00 %
–
[161] INPUT B
–
0.00 %
–
[162] INPUT C
–
SWITCH(A,B)
–
[164] TYPE
–
CURRENT LIMIT
LIMITING [370]
–
FALSE
100.00
%
– [365] MOTOR I LIMIT
–
-100.00
%
–
[623] REGEN I LIMIT
–
CURRENT
–
[366] FEEDBACK SOURCE
–
TRUE
–
[686] REGEN LIM ENABLE
–
ZERO SPEED
AT ZERO SPEED [360] – FALSE
0.00 % – [358] INPUT
–
0.50 %
–
[357] LEVEL
–
0.00 %
–
[359] BAND
–
VALUE FUNC 8
OUTPUT [168]
–
0.00 %
0.00 % – [165] INPUT A
–
0.00 %
–
[166] INPUT B
–
1.00 %
–
[167] INPUT C
–
WINDOW
–
[169] TYPE
–
LOGIC FUNC 1
OUTPUT [183]
–
FALSE
FALSE – [180] INPUT A
–
TRUE
–
[181] INPUT B
–
TRUE
–
[182] INPUT C
–
AND(A,B,!C)
–
[184] TYPE
–
CURRENT FEEDBACK
MOTOR CURRENT [ 66]
–
0.00 %
MOTOR CURRENT [ 67]
–
0.0 A
I MAGNETISING [ 68]
–
0.00 %
I MAGNETISING [ 69] – 0.0 A
I TORQUE [ 70]
–
0.00 %
I TORQUE [ 71]
–
0.0 A
LOAD [ 72]
–
0.00 %
FIELD [ 73]
–
0.00 %
**6.2 A – [ 64] FULL LOAD CALIB
–
**3.6 A
–
[ 65] NO LOAD CALIB
–
0.80
–
[242] POWER FACTOR
–
DIGITAL OUTPUT 1
FALSE – [ 52] VALUE
–
TRUE
–
[ 51] INVERT
–
DIGITAL OUTPUT 2
FALSE – [ 55] VALUE
–
FALSE
–
[ 54] INVERT
–
DIGITAL OUTPUT 3
FALSE – [737] VALUE
–
FALSE
–
[736] INVERT
–
ANALOG OUTPUT 1
0.00 % – [ 45] VALUE –
100.00 %
–
[ 46] SCALE
–
0.00 %
–
[ 47] OFFSET
–
TRUE
–
[ 48] ABS
–
0..+10 V
–
[ 49] TYPE
–
ANALOG OUTPUT 2
0.00 % – [731] VALUE –
66.67 %
–
[732] SCALE
–
0.00 %
–
[733] OFFSET
–
FALSE
–
[734] ABS
–
-10..+10 V
–
[735] TYPE
–
ITEM 4
ITEM 5
ITEM 6
ITEM 2
ITEM 7
feedback link
(7)
(37)
(40)
(24)
(39)
(38)
(41)
(42)
(31)
(28)
(34)
(33)
(1)
(2)
(3)
(4)
(5)
(26)
(27)
(6)
Macro 99: 584S Compatible Application

Table of Contents