89TS 500i
: Remove the support foot (1) from
the retainers (arrows) and pull it
out of the guide on the tank
housing on the side of the tank
filler port
: Remove support foot (1) with air
baffle (2)
: Pull support foot (1) out of the
guide (arrow) of the air baffle (2)
and examine it, replace if
necessary
1307RA344 TG
1
1307RA345 TG
1
2
1307RA346 TG
2
1
: Pry the stop buffer (1) out of the
holes of the air baffle (2)
– Check the wiring harness of the
solenoid valve, replace if
necessary, b 9.6.3
Installation
– Apply STIHL press fluid to the
peg of the stop buffer, b 13
: Push stop buffer (1) into the
holes of the air baffle (2) and
drawing in on the pegs (arrows)
until they enclose the holes
completely
1307RA347 TG
1
2
2
1
1307RA348 TG
– Apply STIHL press fluid to the
guide of the support foot, b 13
: Push the support foot (1) into the
guide (arrow) of the air baffle (2)
: Position the air baffle (1) and
support foot (2) so that the
peg (3) engages behind the
opening and the tab (4) is over
the guide of the wiring harness
– Do not pinch wiring harness
1307RA349 TG
2
1
1307RA350 TG
1
2
3