28 TS 500i
: Press the wiring harness (1) into
the guide so that the protective
tube (2) is flush with the edge
(arrow)
: Press leads into the guide (arrow)
: Fit cover (1) so that the tabs
engage in the mounts (arrows) –
do not pinch the leads when
fitting the cover
1307RA012 TG
2
1
1307RA013 TG1307RA014 TG
1
– Insert and tighten the screw
– Fit the water hose to the solenoid
valve, b 4.1.2
4.2 Cast arm with guard
– Unscrew the banjo screw on the
adjusting lever and remove the
connector with water hose,
b 4.1.1
: Unscrew collar nuts (arrows).
: Relax the ribbed poly V-belt by
turning the hexagon (1) on the
tensioner counterclockwise until
the arrow points to "0" (arrow).
370RA010 TG370RA011 TG
1
: Pull the hose (1) out of the guides
(arrows).
: Remove the screw (arrow).
: Remove the belt guard (1).
: Take out the collar nuts (arrows).
: Remove starter (1)
– Remove ribbed poly V-belt,
b 4.5
370RA013 TG
1
370RA014 TG
1
1307RA009 TG
1