Page #10 background imageLoading...
Page #10 background image
88
2. Storage
Common
If this product is not for immediate use, note the following points when storing it.
2-1 Storage Location
Store the product indoors in a clean, dry location.
Do not store outdoors. Store in a location that is free of moisture, dust, extreme temperature changes, corrosive gases, etc.
2-2 Storage Time
- The storage time should be within the rust prevention time shown below.
- Standard rust prevention specications
External rust prevention Rust prevention oil is applied when shipping from the factory. Check the rust conditions to see
if any rust is forming on the machined surface every six months after shipment. Reapply the rust
prevention oil or any other rust prevention process, if necessary.
Internal rust prevention
Lubrication
Grease lubricated machines Oil lubricated machines
Rust prevention time One year Six months
Storage conditions
Store in an ordinary factory or warehouse in an environment free of
moisture, dust, extreme temperature changes, corrosive gases, etc.
- If for export, or if the storage time is longer than one year, adherence to special rust prevention specications is required.Please
consult with us.
- If the storage time is longer than one year, run for a few minutes under no load once every two to three months. Measure (see P16)
and check the insulation resistance of the motor at that time.
2-3 Using after Storage
- Oil seals are aected by temperature, ultraviolet light and other ambient conditions and can easily degrade. After long storage
periods, inspect before operation, and replace any degraded seals with new seals.
- If the storage time is longer than two years, replace the oil seal and the grease before starting operation.
- At startup, check that there are no unusual noises, vibrations, temperature rises, or other symptoms. For models with brakes, check
that brakes work properly.
If any abnormalities are found, immediately contact the nearest authorized service station.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sumitomo CYCLO and is the answer not in the manual?

Sumitomo CYCLO Specifications

General IconGeneral
Control MethodPWM (Pulse Width Modulation)
Cooling MethodForced air cooling
Protection FeaturesOvercurrent Protection, Overvoltage Protection, Overtemperature Protection, Short Circuit Protection
Operating Temperature0°C to 40°C
Humidity20% to 90% (non-condensing)
DimensionsVaries by model
WeightVaries depending on model (Consult specific datasheet)
Storage Temperature-20°C to +60°C