EasyManua.ls Logo

Sun Microsystems Sun Fire X4100 - F.3.11 Integrated RAID Configuration and Management Screens

Sun Microsystems Sun Fire X4100
278 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix F Serial Attached SCSI BIOS Configuration Utility F-23
If at least one RAID volume is currently configured, you are shown the current
volume(s) for management purposes.
The screens in the RAID configuration and management area are:
Select New Array Type
Create New Array
View Array
Manage Array
F.3.11.1 Select New Array Type Screen
Select the type of array to create, as shown below.
The two new array type options are described in the text that appears on the screen.
No further explanation is needed.
********************************************************************************
* LSI Logic MPT Setup Utility v6.02.00.00 (2005.07.08) *
* Select New Array Type -- SAS1064 *
* *
* *
* Create IM Volume Create Integrated Mirror Array of 2 *
* disks plus an optional hotspare. Data *
* on the primary disk may be migrated. *
* *
* *
* Create IS Volume Create Integrated Striping array of *
* 2 to 8 disks. *
* ALL DATA on array disks will be DELETED! *
* *
* Esc = Exit Menu F1/Shift+1 = Help *
* Enter = Choose array type to create Esc = Return to Adapter Properties *
********************************************************************************
F.3.11.2 Create New Array Screen
The Create New Array screen (shown below) allows you to select disks for a new
array.
TABLE F-10 describes the fields of the screen.
For an IM volume, when the first disk is added you are asked about the data on the
disks. You have two options:
Press M to keep the existing data and migrate to an IM array. Disk synchronization
will occur.
Press D to overwrite existing data, and create a new IM array. All data on all disks
in the array will be deleted. No synchronization occurs.

Table of Contents