2.0 Introduction
- 10 -
2.1.3 Description
The basic configuration consists of one 19-inch rack mounted chassis comprising the following:
l SG-MLRF5 - Metal rack of the SG-System 5 with SG-MP5
l SG-PSU5-600 - 600W power supply unit provides power to all system modules
l SG-PSU5-250 - 250W power supply unit provides power to all system modules
l SG-CPM5 - Central processing module controls all communication to and from receiver modules and printers
l SG-UIB5 - Touch screen user interface
l SG-DRL5-IP - Internet protocol line card
l SG-DRL5-IP PAD - Paddle card for SG-DRL5-IP provides network connection
l SG-MLRF5-RM - Rack mount rails
l SG-S5LFANTR - Line card fan tray
l SG-S5CFANTR - SG-CPM5 fan tray
l SG-S5SERCAB - Y cable for serial connection to the SG-CPM5 for automation/printer
l SG-SYS5MEM4 - Removable EMMC memory
l SG-SYS5DDR31 - DDR3 RAM 1GB
l SG-CPM5BATT - SG-CPM5 real time clock battery
l SG-DRL5 - Single line PSTN card
l SG-DRL5E - Single line PSTN card with backup channel and 2-way audio bridge
l SG-DRL5-2L - Dual line PSTN card
l SG-DRL5PAD - Paddle card for SG-DRL5/DRL5E/DRL5-2L PSTN cards
l SG-ADPT5 - Adapter card for SG-DRL5/DRL5E/DRL5-2L PSTN cards
2.1.4 Specifications
Depth: 27.5 in. (69.85 cm)
Width: 19 in. (48.26 cm)
Height: 7 in. (17.78 cm)
Required rack space: 4U
Dimensions
SG-System 5 UL Electrical:
Input voltage: 100-240 VAC, 50/60Hz.
Input current 600W: 8A max (RMS) @ 100VAC
Input current 250W: 3A max (RMS) @ 100VAC
Backup power supply: External UPS (not supplied)
In a two SG-CPM5 configuration, a redundant SG-PSU5 can be inserted in the second slot. In the event of a SG-PSU5 failure, the redundant SG-
PSU5 automatically assumes operation. These modules are hot swappable (can be removed and replaced while the system is in operation) if a working,
redundant SG-PSU5 is installed. Both PSU units used in the system must have the same power rating.
Environmental:
Temperature: 0-49°C (32 - 120°F)
Humidity: 93%RH, non-condensing
Accounts:
ULC Line Security Levels: A1-A4 (active channels) or P1-P3 (passive channels)
Printers (UL/ULC Listed Installations):
Serial: Seiko DPU-414
DACT Compatible communication formats (ULC Passive channels): SIA, CID
Encryption: AES 128 bit
2.2 System features
2.2.1 SG-System 5
l Reduced size of 4U in height for improved receiver room logistics management
l CMS access to visual verification files through SG-System 5 Console
l Upgradeable through the SG-System 5 Console
l Enhanced hardware diagnostics via SG-System 5 Console
l Static IP for programming of network protocols
l Real time system status via intuitive user touchscreen interface
l Supports visual verification features for DSC PowerSeries Neo
l Monitor up to 1,474,560 IP communicators (Cellular or Ethernet) with up to 24 IP line cards