Appendix D: Events and Messages
- 140 -
SG-DRL5-IP messages
NOTE: (ss) represents the line card slot
(cc) represents the table number (1, 2 or 3)
Description/event COMPUTER PRINTER
Transmitter that has connected to the
receiver is unencrypted (where IP is trans-
mitters IP, and X is the transmitters
account, oo is the slot and CC is the channel
number)
000001[#XXXXXXXXXX|NNC* IP.IP.IP.IP*]
SG -00-001-XXXXXXXXXX-
NC-*TRANSMITTER
UNENCRYPTED IP.IP.IP.IP*
Transmitter has successful had encryption
enabled (where IP is transmitters IP, and X
is the transmitters account)
000001[#XXXXXXXXXX|NYZ0010]
SG -00-001-XXXXXXXXXX-
YZ-*ENCRYPTION
ENABLED - IP.IP.IP.IP*
The transmitter is not able to support encryp-
tion request(where IP is transmitters IP, and
X is the transmitters account)
No Automation Message
SG -01-001-XXXXXXXXXX-
-*ENCRYPTION NOT
SUPPORTED - IP.IP.IP.IP*
Transmitter has not successful had encryp-
tion enabled (where IP is transmitters IP,
and X is the transmitters account)
001001[#XXXXXXXXXX|NYZ0011]
SG -01-003-XXXXXXXXXX-
YZ-*ENCRYPTION SET FAIL
- IP.IP.IP.IP*
Transmitter has successful had encryption
disabled (where IP is transmitters IP, and X
is the transmitters account)
000001[#XXXXXXXXXX|NYZ0012]
SG -00-001-XXXXXXXXXX-
YZ-*ENCRYPTION
DISABLED - IP.IP.IP.IP*
Transmitter has been added to Account
table(where X is the transmitters account)
000001[#XXXXXXXXXX|NXA*IP.IP.IP.IP*]
SG -00-001-XXXXXXXXXX-
XA-*Unknown Account
IP.IP.IP.IP*
Transmitter with supervision enabled - has
turned off supervision (where IP is trans-
mitters IP, and X is the transmitters
account)
001001[#XXXXXXXXXX|NYG*IP.IP.IP.IP*]
SG -01-001-XXXXXXXXXX-
YG-*Transmitter Supervision
Disable IP.IP.IP.IP*
Remote shutdown has been sent to the trans-
mitter.
Where:
XXXXXXXXXX is the account code of
the transmitter
IP.IP.IP.IP is the current IP address of the
transmitter
000001[#XXXXXXXXXX|NYX0001]
SG -00-001-XXXXXXXXXX-
YX-*TRANSMITTER
SHUTDOWN - IP.IP.IP.IP*
Transmitter has not successful completed
the shutdown command (where IP is trans-
mitters IP, and X is the transmitters
account)
001001[#XXXXXXXXXX|NYX0002]
SG -01-001-XXXXXXXXXX-
YX-* TRANSMITTER
SHUTDOWN FAIL
IP.IP.IP.IP*
Transmitter has been deleted from the
account table VIA the console
Where:
XXXXXXXXXX is the account code of
the transmitter
IP.IP.IP.IP is the current IP address of the
transmitter
001003[#0000000001|NJX* IP.IP.IP.IP *]
SG -01-003- XXXXXXXXXX
-JX-*Transmitter Deleted
IP.IP.IP.IP *
Account added to the account table VIA the
console
Where:
# is the number of accounts added
X is the transmitters account
No Automation
SG -01-000-0000--Console SET
IP Account (#)
XXXXXXXXXX
Firmware Update Start 001001[#0000|NMIss00]
SG -01-001-0000-NMIss00-
Firmware Update Initiated
Firmware Update Failed 001001[#0000|NMIss01]
SG -00-0FF-0000-NMIss01-
Firmware Update Failed