7.0 SG-DRL5/DRL5E/DRL5-2L PSTN Line Cards
- 111 -
Option Value Code
165/265 62 CLOSING
166/266 E5 OPENING
167/267 00 SERVICE
168/268 E4 MEDICAL*
169/269 61 MESSAGE
16A/26A F2 RESTORE
16B/26B C6 PERIODIC TEST
16C/26C C7 REPORT
16D/26D E6 GROUP CLOSING
16E/26E 50 GROUP OPENING
16F/26F A6 ZONE BYPASS
SYSTEM TROUBLE
CANCEL
*Use only with Model SG-SystemIV CE.
SG-System IV CE is not UL Listed.
Refer also to the Library Select Option 171/271. The English Printer Library is provided and can be selected by programming the event codes to the cor-
responding word.
For example, if the words 'exit alarm' are required when the alarm code 1 is received in 3/1 (or 4/1 formats), Option 161/261 must be programmed as
'90'.
Refer to Appendix A for a list of available words.
SG-DRL5 Option 170/270: Automation Common Event Code
Default (00)
Some central station software packages are unable to process an alarm using the event codes listed in the Decoding Library. Where a central station mon-
itors thousands of accounts belonging to different companies, the same reporting codes may have different meanings for different companies. Because
of this, the individual event codes in Options 130/230 through 15F/25F cannot accurately represent the alarm condition.
To overcome this, Option 170/270 may be programmed as indicated below:
Program Operation:
Setting Description
00 Use individual event codes to computer.
20, 30-
39 &
41-5A
Use common event codes (space, 0-9, A-Z). When using common event codes, Sur-Gard
recommends that either hexadecimal code '5A' (ASCII 'Z') or hexadecimal code '41' (ASCII
'A') be used. The 'Space' character (Hex 20) can be used as the common event code with cer-
tain automation software packages to avoid account code database changes when switching
over from other brand receivers to the Sur-Gard receiver.
B0-DF ('0'-'9', 'A'-'Z' with the most significant bit set). This range functions in the same way as 30-39,
41-5A, with the exception that, for the Superfast Ademco Format, the Printer Message text is
not output.
For example: "01-002-1234-A4-".
SG-DRL5 Option 171/271: Library Select
Default (04)
Determines how to use Printer Words Options.
00 No printer words.
01 Printer words options used for 1-digit reporting code formats only; other uses predefined library.
02 Printer words options used for 2-digit reporting code formats only; other uses predefined library.
03 Printer words options used for 3-digit reporting code formats only; other uses predefined library.
04 Printer words options used for 1-digit and 2-digit reporting code formats only; other uses predefined library.
05 Printer words options used for 1-digit, 2-digit and 3-digit reporting code formats.
NOTE: Option 171/271 is ignored when using SIA, ITI, Contact-ID, ACRON, MODEM II, MODEM IIE, MODEM IIIa², FBI SuperFast,
BFSK, ADEMCO Super Fast and SK FSK1, 2 formats.