EasyManua.ls Logo

TECE Lux Mini - Page 50

TECE Lux Mini
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Position Function
1 Pause function “o
2 Pause function “on
3 Flush time 2 s
4 Flush time 2.5 s
5 Flush time 3 s
6 Flush time 3.5 s
7 Flush time 4 s
8 Flush time 5 s
9 Flush time 6 s
10 Flush time 8 s
11 Flush time 10 s
12 Pre-rinsing “o
13 Pre-rinsing 0.5 s
14 Pre-rinsing 1 s
15 Pre-rinsing 2 s
16 Hygiene flush o
17 Hygiene flush 24 h
18 Hygiene flush 255 h
19 Sensor sensitivity “low”
... ...
23 Distance “standard”
24 Distance “short”
25 Distance “long”
... ...
28 Factory setting
29 Urinal covers “o”
30 Urinal covers “on”
= factory setting
Approximately five seconds after being connected to the
power supply, TECE electronics can be programmed in the
first  minutes. Each configurable function is assigned a
position.
In programming mode, the electronics can be setwith the
magnetic key. In standard mode, only the cleaning function
can be activated with this key.
Cleaning function:
When cleaning the urinal, automatic flushing is generally
not required as the cleaning agent needs time to take
eect. For this reason, flushing can be delayed by 
minutes.
Pre-flush (optional):
(Duration – seconds) Briefly humidifies the ceramic
before use, preventing adhesion of urine. Desired side
eect: The pre-flush stimulates the urge to urinate.
Pause function (optional):
The volume of water is automatically reduced if the urinal
is flushed at intervals of less than two minutes. A clean-
ing flush takes place  minutes after the last water-sav-
ing flush.
Variable flush time:
(Duration – seconds) The flush volume can be
adapted to requirements throughout the flush time.
Distance:
The modern autofocus sensor optical system operates
reliably in varying construction situations. Nevertheless,
the optical system's detection range can be changed on
extremely small or large urinal systems.
Hygiene flush (optional):
If this function is activated, a regular clean flush prevents
the siphon from drying out and emitting unpleasant
smells, and also prevents residues from being deposited
(choice of  or  hours after the last flush).
Siphon refill (optional):
Modern urinals generally suck the siphon contents
completely away and then refill enough water to fill the
siphon back up again. If this does not work, the refill
function of the TECE electronics can be activated, and a
short flush impulse fills the siphon up.
This is how to program the TECE electronics:
Hold the programming key briefly
in front of the sensor window.
The programming mode starts with
a quick series of short beeps.
After the start-up phase, a sequence of the same beeps
can be heard. Count the beeps until you reach your
desired function.
Now remove the programming key. A long beep indi-
cates that the programming key has been removed.
Example: Setting the flush time to three seconds
. . . .
Hold the programming
key in front of the
sensor
Remove the program-
ming key
Start 1 2 3 4 5 OK
Count the individual beeps
until the desired position is
reached
TECE flush plates – TECEplanus infrared electronics
-
Flush plates