If necessary, the urinal electronics can be programmed.
See the following programming instructions for more infor-
mation.
The installed cover can be removed from the flush plate
using the bow-type handles included in the installation
frame's scope of supply. Only position the suction cups on
the cover to be removed.
The steps for installing the TECEfilo urinal electronics with
the .V battery variant are virtually the same.
Programming the urinal electronics
To program the TECEfilo urinal electronics, the program-
ming key provided in the scope of supply is required. The
TECE electronics can be programmed during the first 30
minutes after connection to the power supply. In the event
of a power failure, the last settings saved are retained.
Each configurable setting is assigned a position on the
remote control.
Position Function
1 Pause function “o”
2 Pause function “on”
3 Flush time 1 s
4 Flush time 2 s
5 Flush time 3 s
6 Flush time 4 s
7 Flush time 5 s
8 Flush time 6 s
9 Flush time 7 s
10 Flush time 8 s
11 Flush time 9 s
12 Flush time 10 s
13 Pre-rinsing “o”
14 Pre-rinsing 0.5 s
15 Pre-rinsing 1 s
16 Pre-rinsing 2 s
17 Hygiene/interval flush “o
18 Hygiene/interval flush 24 hrs
19 Hygiene/interval flush 72 hrs
20 Hygiene/interval flush 168 hrs
21 Refill "o"
22 Refill “on” (refill for 2 s after flushing for 2 s)
23 Sensor sensitivity “sensitive”
24 Sensor sensitivity “standard”
25 Hygiene flush volume small (5 s)
26 Hygiene flush volume medium (15 s)
27 Hygiene flush volume big (30 s)
28 Reset to factory settings
29 Urinal covers “o
30 Urinal covers “on”
= factory setting
During the programming phase, a red diode flash-
es in the centre of the sensor field as soon as a
person enters the area. This diode acknowledges
that the programming mode is activated. In addi-
tion, it indicates the exact position of the program-
ming key.