BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.58
7.2.16. DISASSEMBLING THE WEIGHT STACK MOTOR
Figure 7.2.16-1
Follow the steps described in paragraphs 7.2.14.
“Disassembling the weight stack selection
system” and 7.2.15. “Disassembling the weight
stack selection chain”.
1. Loosen the dowel a using a 2.5-gauge
hexagonal T-wrench.
2. Slide the pinion b from the motor shaft.
3. Unscrew the 3 screws c, using a 4-gauge
hexagonal T-wrench.
4. Remove the MOTOR.
To reassemble the MOTOR, follow the above
steps in reverse order.
When the operation is complete, adjust
the tension of the weight stack selection
chain, the position of the weight stack
and plate selection system as described
in paragraphs 8.1., 8.10. and 8.9. .