BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.178
7.5.9. DISASSEMBLING THE ELECTRICAL BOX
Figure 7.5.9-1
Follow the steps described in paragraph 7.5.8.
“Disassembling the front guard”.
1. Unscrew the screw a using a 4-gauge
hexagonal T-wrench.
2. Open the cover of the ELECTRICAL BOX.
3. Disconnect the cable connectors c.
4. Unscrew the 4 nuts b (2 on each side) using a
10-gauge tube wrench.
5. Remove the ELECTRICAL BOX.
To reassemble the ELECTRICAL BOX, follow
the above steps in reverse order.