7.4.19. DISASSEMBLING THE CROSS
Figure 7.4.19-1
Follow the steps described in paragraphs 7.4.9.
“Disassembling the weight stack cover”, 7.4.10.
“Disassembling the additional weight”, 7.4.11.
“Disassembling the encoder”, 7.4.15.
“Disassembling the weight stack selection
system” and 7.4.18. “Disassembling the cross
stops”.
1. Loosen the 2 screws a using a 4-gauge
hexagonal T-wrench.
2. Remove the 2 counter-weights
Figure 7.4.19-2
3. Use a special tool c to compress all of the
weight stack plate springs.
4. Remove the CROSS by sliding it upward.
To reassemble the CROSS, follow the above
steps in reverse order.
To reassemble the CROSS, it is not
necessary to compress the plate springs;
simply press it down.