BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.300
7.8. ROWING TORSO
7.8.1. DISASSEMBLING THE DISPLAY
Figure 7.8.1-1
1. Shut off the equipment and unplug the power
cord from the wall socket.
2. Use a medium Philips screwdriver to
unscrew the 4 self-tapping screws a holding
the DISPLAY.
Hold the DISPLAY up before
unscrewing the last screw.
Figure 7.8.1-2
3. Open the DISPLAY.
To remove the DISPLAY:
1. Disconnect the connectors b.
2. Remove the DISPLAY.
To re-mount the display, follow the above steps
in reverse order.