Page 8.13
8.2.6. SHOULDER PRESS
Figure 8.2.6-1
1. With the seat in position 9, adjust the
position of the easy start lever so that it
respects the measurements shown in the
drawing.
2. To do so, adjust the position of the limit
switch under the easy start lever support by
regulating the screw and nut with a 17-gauge
wrench.
3. Connect and power all cables.
4. Adjust the starting position of the levers so
that:
• They are horizontal (using the level);
• They have the maximum stroke (limit
switches as tight as possible).
5. To do so, adjust the position of the limit
switch by regulating the screw and nut with a
17-gauge wrench.
6. Adjust the ending position of the levers so
that:
• They are horizontal (using the level);
• The right lever does not strike the left.
7. To do so, adjust the position of the limit
switch by regulating the screw and nut with a
17-gauge wrench.