7.3.13. DISASSEMBLING THE SELECTOR BRUSH
Figure 7.3.13-1
Follow the steps described in paragraph 7.3.7.
“Disassembling the Plexiglas weight stack
guard” limited solely to the internal part.
1. Switch the machine on.
2. Follow the steps described in paragraph 9.2
“Configuring the technical parameters” until
the final procedure that moves the brush into
position as shown in the figure alongside.
3. Use a 2.5-gauge wrench to unscrew the 5
screws a.
4. Remove the SELECTION BRUSH.
5. You may also replace the solenoid b by
removing it with pliers.
To reassemble the SELECTION BRUSH, follow
the above steps in reverse order