BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 2.35
2.6.1.1. Connectors
• Power socket
Name Type of connector Connection
CN11 3 male Faston 6.3x0.8 110/220 Vac line: phase, neutral, earth
• Power switch
Name Type of connector Connection
CN13 2 male Faston 6.3x0.8 110/220 Vac line: phase, neutral
CN14 2 male Faston 6.3x0.8 110/220 Vac line: phase, neutral
• Fuse
Name Type of connector Connection
CN15 2 male Faston 4.8x0.5 110/220 Vac line: phase, neutral
CN16 2 male Faston 4.8x0.5 110/220 Vac line: phase, neutral
• Filter
Name Type of connector Connection
CN17 3 male Faston 6.3x0.8 110/220 Vac line: phase, neutral, earth
CN18 2 male Faston M5 screw slot 110/220 Vac line: phase, neutral, earth
• Selector switch
Name Type of connector Connection
CN19 Contacts to be soldered 110/220 Vac line: phase, neutral
• Power supply (order code 0WA040)
Name Type of connector Connection
CN1 6-pin male PANDUIT 110/220 Vac line: phase, neutral, earth
CN2 6-pin male PANDUIT Low voltage: +12 Vdc, +5 Vdc, ground
CN7 Male Faston for printed circuit 6.3x0.8 Earth contact
• CPU Board (labeled GF961223 - order code 0WQ067)
Name Type of connector Connection
K1 4-pin male AMP MODU I Low voltage: +12 Vdc, +5 Vdc, ground
K3 6-pin male AMP MODU II Serial: RS-232 to FPGA
K4 9x2-pin male AMP MODU II Signals: I/O connection
K5 4x2-pin male AMP MODU II Signals: I/O connection
K6 4-pin male AMP MODU II TLCBR
K15 6-pin male AMP MODU II External serial port

Table of Contents