BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 2.52
• Solenoid interface board (labeled GF970405 - order code 0WQ080)
Name Type of connector Connection
CN1 4-pin male AMP MODU II Signals: CPU connection
CN2 2-pin female AMP MNL Solenoid
CN3 2-pin terminal board 18 Vac 1A power supply
• Weight stack motor interface board (labeled GF970305 - order code 0WQ119)
Name Type of connector Connection
CN1 6-pin male AMP MODU II Signals: CPU connection
CN2 2-pin terminal board 18 Vac 5A power supply
CN3 6-pin female AMP MNL 24 Vdc motor with reed
• Seat motor interface board (labeled GF991206 - order code 0WQ00011)
Name Type of connector Connection
CN1 6-pin male AMP MODU II Signals: CPU connection
CN2 2-pin terminal board 18 Vac 5A power supply
CN3 6-pin female AMP MNL 24 Vdc motor with reed
CS1 2-pin open male AMP MINIFIT Safety sensor input signal
CS2 2-pin male AMP MODU II Reset
• FPGA Board (labeled GF970601 - order code 0WQ069)
Name Type of connector Connection
CN1 8-pin male AMP MODU II Signals: connection with encoder
CN2 6-pin male AMP MODU II RS-232 serial to CPU
CN3 4-pin male AMP MODU I Low voltage: +12 Vdc, +5 Vdc, ground
CN4 4-pin male AMP MODU I Low voltage: +12 Vdc, +5 Vdc, ground
• Patch cords
Name Type of connector Connection
CN21 6-pin open male AMP MNLI Weight stack motor and reed power
supply
CN23 6-pin open male AMP MODU II Encoder signals
CN24 2-pin open male AMP MODU II Zero sensor signal
CN25 2-pin open male AMP MODU II Zero sensor signal
CN26 4-pin open male AMP MODU II Solenoid power supply
CN27 4-pin open male AMP MODU II Solenoid power supply
CN28 2-pin open female AMP MINIFIT Safety sensor signal
CN29 2-pin open male AMP MINIFIT Safety sensor signal

Table of Contents