RUN XT: Service & Maintenance Manual - rev. 2.0
Page 6.22
(ground) of connector CN1 on the inverter interface board. When the belt is halted the
measured value should be 0 Vdc, whereas immediately after pressing the “Start” key on the
display the reading should rapidly increase to reach a fixed value corresponding to the selected
speed. The variation of the signal must be accompanied by a corresponding variation in the belt
speed: see Table 6.6-1 or Table 6.6-2.