EasyManua.ls Logo

TECO JSDG2S Series - 4-4 Program JOG Operation

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-11
4-4 Program JOG Operation
Program JOG operation is the function to execute continuous operations using preset operation modes
(stroke direction, stroke moving distance, stroke moving speed, stroke acceleration/deceleration time
and stroke stop time).
This function is the same as JOG operation; action confirmation and simple positioning actions of the
servo motor can be executed when no host device is connected in settings.
§ Confirmation items before execution
The following items must be confirmed before executing program JOG operations.
The power of the main circuit is ON
No alarm occurred
In the servo OFF status
Please consider the movable range and safe moving distance of the machine used to set the
moving distance and moving speed
No CW/CCW drive prohibition
§ Supplementary items
Even program JOG operation is position control, but the pulse command input to the servo unit
cannot be used.
CW/CCW drive prohibition function is effective.

Table of Contents

Related product manuals